Functional MRI Pipeline

The BRC Functional MRI Pipeline (BRC_functional_pipeline) preprocesses resting-state and task-based fMRI data from raw NIFTI through distortion correction, motion correction, registration to T1 and standard space, ICA-AROMA noise removal, temporal filtering, and spatial smoothing.


Structural prerequisite

EPI-to-T1 registration and standard-space warping require a completed Structural Pipeline run for the same subject.

The pipeline supports multiple susceptibility distortion correction strategies (TOPUP spin-echo, Siemens/GE field maps, or none), flexible slice-timing correction via FSL or SPM, and modular physiological noise removal. The default output is a cleaned, registered 4D fMRI volume in standard space, ready for group-level analysis.


Pipeline Stages

Stage Script Description
Part 1 fMRI_preproc_part_1.sh Gradient distortion correction, EPI distortion correction, spin-echo bias field
Part 2 fMRI_preproc_part_2.sh Motion correction, slice timing correction, EPI-to-T1 registration, one-step resampling
Part 3 fMRI_preproc_part_3.sh Intensity normalisation, ICA-AROMA, physiological noise removal, temporal filtering, spatial smoothing, QC

Quick Start

export BRC_GLOBAL_SCR=/opt/brc/global/scripts
export BRC_FMRI_SCR=/opt/brc/BRC_functional_pipeline/scripts
export FSLDIR=/usr/local/fsl
source ${FSLDIR}/etc/fslconf/fsl.sh

fMRI_preproc.sh \
    --input   /data/sub-001/func/sub-001_task-rest_bold.nii.gz \
    --path    /data/study \
    --subject sub-001 \
    --dcmethod TOPUP \
    --SEPhaseNeg /data/sub-001/fmap/se_AP.nii.gz \
    --SEPhasePos /data/sub-001/fmap/se_PA.nii.gz \
    --echospacing 0.00058 \
    --unwarpdir y- \
    --fmrires 2

Compulsory Arguments

Argument Description
--input Full path to the 4D fMRI NIFTI file
--path Output directory (absolute path)
--subject Subject identifier

Optional Arguments

Argument Default Description
--mctype MCFLIRT6 Motion correction: MCFLIRT6 (6 DOF), MCFLIRT12 (12 DOF), or EDDY
--dcmethod NONE Distortion correction: TOPUP, SiemensFieldMap, GeneralElectricFieldMap, NONE
--fmriscout NONE Single-band reference (SBRef) image
--slice2vol off Slice-to-volume motion correction
--slspec — JSON slice specification file
--SEPhaseNeg NONE Spin-echo field map — negative PE direction
--SEPhasePos NONE Spin-echo field map — positive PE direction
--fmapmag NONE 4D magnitude image for Siemens-style field map
--fmapphase NONE 3D phase difference for Siemens-style field map
--echodiff NONE Echo time difference for Siemens field map
--echospacing — Effective echo spacing of SE field map (seconds)
--echospacing_fMRI 0.0 Echo spacing of fMRI data (seconds), if different from SE field map
--unwarpdir — Unwarp direction: y (PA), y- (AP), x (RL), x- (LR)
--biascorrection NONE Bias correction: NONE or SEBASED (spin-echo based; requires TOPUP)
--intensitynorm off Grand-mean intensity normalisation
--stcmethod 0 Slice timing correction method (0=none, 1–8; see below)
--slstiming — Custom slice order/timing file
--fwhm 0 Spatial smoothing sigma (mm); 0 = no smoothing
--noaroma off Disable ICA-AROMA noise removal
--fmrires 2 Target output resolution (mm)
--tempfilter 0 High-pass temporal filter cutoff (seconds); 0 = no filtering
--name rfMRI Output folder name
--noqc off Disable QC analysis
--clean off Delete all intermediate files after completion
--delvolumes 0 Number of volumes to remove from the start of the timeseries
--physin — Physiological data file (text format)
--samplingrate 100 Physiological data sampling rate (Hz)

Slice Timing Correction Methods

Code Method Description
0 None No slice timing correction (default)
1 SPM Interleaved acquisition (0, 2, 4 … 1, 3, 5)
2 SPM Forward acquisition (0, 1, 2, …)
3 SPM Backward acquisition (n, n-1, n-2, …)
4 FSL Bottom-to-top
5 FSL Top-to-bottom
6 FSL Interleaved
7 FSL Custom slice order file (--slstiming)
8 FSL Custom slice timings file (--slstiming)

Processing Steps

Part 1 — Distortion Correction

  1. Gradient distortion correction: applies gradient nonlinearity correction if coefficients are supplied; otherwise creates identity warp fields for pipeline compatibility
  2. EPI distortion correction (EPI_Distortion_Correction.sh): runs FSL topup on spin-echo pair or prepares Siemens/GE field maps
  3. Spin-echo bias field (Compute_SpinEcho_BiasField.sh): estimates receive-coil bias from spin-echo images (only when biascorrection=SEBASED)
  4. Parameter file generation (Generate_Parameter_File.sh): writes acquisition parameter files required by eddy and topup

Part 2 — Motion Correction and Registration

  1. Volume deletion (EddyPreprocessing.sh): removes leading volumes specified by --delvolumes
  2. Motion correction (MotionCorrection.sh): mcflirt (6 or 12 DOF, calls mcflirt.sh) or eddy-based within/between-volume correction (eddy_cuda.sh)
  3. Slice timing correction (Slice_Timing_Correction.sh): FSL slicetimer or SPM-based correction via run_spm_slice_time_correction.m
  4. EPI-to-T1 registration (EPI_2_T1_Registration.sh): boundary-based registration using epi_reg_dof.sh; concatenates with T1→MNI warp for single-step resampling
  5. One-step resampling (One_Step_Resampling.sh): applies the full distortion + motion + registration warp in a single applywarp call to avoid cascading interpolation artefacts

Part 3 — Cleaning and QC

  1. Intensity normalisation (Intensity_Normalization.sh): scales 4D data to a grand-mean intensity of 10,000 (when --intensitynorm is set)
  2. ICA-AROMA (ICA_AROMA/ICA_AROMA.py): identifies and removes motion-related artefact components using a pre-trained classifier; produces a non-aggressively denoised output
  3. Physiological noise removal (Physiological_Noise_Removal.sh): models and removes cardiac and respiratory noise using FSL fabber / PNM if physiological traces are provided
  4. Temporal filtering (Temporal_Filtering.sh): applies high-pass filter using FSL bptf
  5. Spatial smoothing (Spatial_Smoothing_Noise_Removal.sh): Gaussian smoothing with specified FWHM
  6. Data organisation (Data_Organization.sh): moves processed files into the final BRC output hierarchy
  7. QC analysis (QC_analysis.sh, run_QC_analysis.m): generates motion parameters, tSNR maps, and summary statistics

ICA-AROMA

ICA-AROMA is a Python-based tool that uses four spatial and temporal features to classify ICA components as signal or noise (motion-related). It includes:

  • Edge fraction (proximity to brain edge)
  • High-frequency content (power spectrum)
  • Maximum real data correlation with CSF mask
  • Maximum real data correlation with out-of-brain mask

The classifier was trained on manual component labels and operates without subject-specific thresholds. Non-aggressive denoising regresses only the noise time courses, preserving shared variance between signal and noise.


Dependencies

Tool Used For
FSL (mcflirt, flirt, fnirt, applywarp, topup, slicetimer) Motion correction, registration, distortion correction
Python + scikit-learn ICA-AROMA
MATLAB / SPM Slice timing correction (SPM methods), QC analysis
BRC_GLOBAL_SCR Logging
BRC_FMRI_SCR All pipeline sub-scripts

Key Output Files

All paths are relative to <path>/<subject>/analysis/rfMRI/ (or the name set by --name).

File Description
processed/func2std.nii.gz Final cleaned fMRI in MNI152 standard space
processed/func2str.nii.gz Final cleaned fMRI in T1 native space
reg/func2str.mat EPI → T1 affine
reg/func2std_warp.nii.gz EPI → MNI warp field
ICA_testout.ica/ Melodic ICA output (AROMA components)
ICA_testout_denoised.nii.gz ICA-AROMA denoised 4D timeseries
mc/prefiltered_func_data_mcf.par Motion parameters (6 DOF)
QC/ tSNR map, motion plots, summary statistics
log/log.txt Full processing log

Script Reference

Script Purpose
fMRI_preproc.sh Entry point — argument parsing and job dispatch
fMRI_preproc_part_1.sh Part 1 dispatcher: GDC, EPI distortion, bias
fMRI_preproc_part_2.sh Part 2 dispatcher: motion, STC, registration, resampling
fMRI_preproc_part_3.sh Part 3 dispatcher: normalisation, AROMA, filtering, smoothing, QC
Generate_Parameter_File.sh Write TOPUP/EDDY acquisition parameter files
EPI_Distortion_Correction.sh TOPUP or fieldmap-based distortion correction
Compute_SpinEcho_BiasField.sh SE-based receive-coil bias estimation
EddyPreprocessing.sh Volume deletion and eddy current pre-steps
MotionCorrection.sh MCFLIRT or EDDY motion correction
mcflirt.sh FSL mcflirt wrapper
eddy_cuda.sh GPU-accelerated eddy wrapper
Slice_Timing_Correction.sh FSL/SPM slice timing correction
EPI_2_T1_Registration.sh Boundary-based EPI-to-T1 registration
epi_reg_dof.sh epi_reg wrapper with configurable DOF
One_Step_Resampling.sh Combined warp application (distortion+motion+reg)
Apply_Registration.sh Apply pre-computed registration transforms
Intensity_Normalization.sh Grand-mean intensity scaling
Physiological_Noise_Removal.sh Cardiac/respiratory noise modelling
Temporal_Filtering.sh High-pass temporal filtering
Spatial_Smoothing_Noise_Removal.sh Gaussian spatial smoothing
Data_Organization.sh Move files into BRC output hierarchy
QC_analysis.sh QC metrics and report generation
ICA_AROMA/ICA_AROMA.py ICA-AROMA main classifier
ICA_AROMA/ICA_AROMA_functions.py AROMA feature extraction functions